Options
2009
Conference Paper
Titel
PCD "Pressure Control Device" for the prevention of water hammer in pipe systems
Alternative
PCD "Pressure Control Device" zur Vermeidung von Druckstößen in Rohrleitungen
Abstract
Due to control, start-up and shut-down processes as well as operational disturbances in a process plant flow rate, pressure fluctuations and surges may occur (e.g. water hammer, cavitation hammer). These pressure surges can lead to damages of plant's equipment (valves, pumps, pipe bends) up to leakage of the pipe system that seriously decrease plant availability and safety. In this contribution, the results of experiments at UMSICHT's own test rig as well as some new methods of prevention of pressure surges are presented.
;
Durch Regelvorgänge, An- und Abfahrprozesse sowie Betriebsstörungen treten erhebliche Durchsatz- und Druckschwankungen auf (z.B. Druckstöße, Kavitationsschläge), die zu Schäden an verschiedenen Teilen einer verfahrenstechnischen Anlage (Armaturen, Pumpen, Rohrhalterungen) bis zu Leckage / Bruch von Rohrsystemen führen können. Diese Schäden können die Anlagenverfügbarkeit und Anlagensicherheit erheblich beeinträchtigen. In diesem Beitrag werden die Untersuchungsergebnisse an der Versuchsanlage von Fraunhofer UMSICHT und neue Methoden zur Vermeidung von Druckschwankungen und Druckstößen in Rohrleitungen präsentiert.
Author(s)