Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

The multi-sensor Tomolibri® - measuring using computed tomography

 
: Kasperl, S.; Franz, M.; Maisl, M.; Neumayer, D.; Stotz, M.

:
Volltext urn:nbn:de:0011-n-1036370 (2.2 MByte PDF)
MD5 Fingerprint: 3ea52aed61285da670f42d6e8786e007
Erstellt am: 27.8.2009


International Committee for Non-Destructive Testing -ICNDT-; Chinese Society for Non-destructive Testing -ChSNDT-:
17th World Conference on Nondestructive Testing : Shanghai, China, October 25 - 28, 2008
Shanghai, 2008
Paper 95
World Conference on Nondestructive Testing (WCNDT) <17, 2008, Shanghai>
Englisch
Konferenzbeitrag, Elektronische Publikation
Fraunhofer IZFP ()
Fraunhofer IIS ()
x-ray; computed tomography; beam hardening; artefact correction; multisensor measuring device

Abstract
Computed tomography is used as a tool for non-destructive testing in the industry as means for quality assurance and development. For some time now, industrial CT systems have been in use for tasks in the field of dimensional measurements. The advantage of this technique is the ability to completely and non-destructively scan and measure the surface of complex parts. Within a joint research project of the Fraunhofer Institutes IPA, IZFP, IOF and IIS under leadership of the Fraunhofer IPA, a so-called "Tomometer" was developed. This device realises the entire process chain in measuring, ranging from data acquisition to metrological processing. The multi-sensor Tomolibri® combines a high resolution CT system with a an optical sensor developed by the Fraunhofer IOF.. This surface scanner is based on fringe projections and provides 3D coordinates of the visible surface with an accuracy of a few micrometers This article depicts the components of this multi-sensor device and, using selected examples, shows the application of the second sensor for refeeding the CT data, for using the synchronous artefact reduction as well as software tools for metrological evaluation.

: http://publica.fraunhofer.de/dokumente/N-103637.html