Options
1983
Conference Paper
Titel
Shortening and standardizing the pulse shape of piezoelectric transducers in the Megahertz region
Abstract
The optimization of ultrasonic pulse shape by digitally generated excitation functions is demonstrated. Experiments show correspondence of objective function and easured pulse shape. Shortening of pulses down to 1/5 of "natural" -20 dB idth was achieved. The enhanced axial resolution can be useful in nondestructive testing and medical diagnosis with ultrasonics.
Konferenz