Abstract
In the actual state of SHAM test analysis the key results can be summarized as follows: - the design of all configurations proved to be conservative, since all stesses were limited to the allowable values. Forces in supports were partly under- and partly overestimated. - The piping system could be exposed to at least 300% of the design loads in 5 different support configurations. The HDR-configuration which was not designed for seismic loads withstood a 200% SSE load without any damage or global residual deformation. - The Energy Absorbers behaved in all aspects as expected. The replacement of 6 snubbers by only 3 Energy Absorbers was sufficient to keep pipe stresses within the limits. - The replacement of all snubbers by Seismic Stops kept the pipe stresses within the allowable limits. - The stiff NRC-configuration was tested up to 8 times the design loads. In the 600% SSE test 3 snubbers failed. They were not replaced for the 800% SSE tests, during which another snubber failed from o verloading. Nevertheless, the pipe was not damaged and showed no global plastic deformation. - The flexible support configuration designed by Siemens/KWU could be exposed to 8 times the design loads without any problems. - In the highest stressed points of the pipe strain ranges of 1.5% were measured and residual strains accumulated to 1.2%. - Seismic margins of rigid struts are clearly greater than the expected factor of 3 to 4. None of the struts failed in any of the tests although overloadings of up to a factor of 9 were realized.
Author(s)
Malcher, L.
Schrammel, D.G.
Steinhilber, H.
Mainwork
Structural Mechanics in Reactor Technology. Vol.K2. Seismic Response Analysis and Design  
Conference
International Conference on Structural Mechanics in Reactor Technology (SMIRT) 1989  
Language
English
Fraunhofer-Institut für Betriebsfestigkeit und Systemzuverlässigkeit LBF  
Keyword(s)
  • Dämpfung

  • Erdbebensimulation

  • Ganzzellenversuch

  • Kraftwerk

  • Reaktorsicherheit

  • Rohrleitung

  • servohydraulische Anregung

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024