Mounting, cementing and handling of micro-optical elements

 
: Guyenot, V.; Eberhardt, R.; Risse, S.; Tittelbach, G.

Parriaux, O.M. ; Centre National de la Recherche Scientifique -CNRS-, Paris:
Micro-optical technologies for measurement, sensors and microsystems
Bellingham, Wash.: SPIE, 1996 (Europto series)
ISBN: 0-8194-2169-3
pp.105-116
International Symposium on Laser, Optics and Vision for Productivity in Manufacturing <1, 1996, Besancon>
English
Conference Paper
Fraunhofer IOF ()
assembling; cementing; equipment; gripper; handling; micro component; micro-mounting; microoptics

Abstract
The greatest hinderence to wider applications of micro-optics is the inefficience of the mounting process. Currently there are attempts to remedy this through transferring the know-how from the manufacture of great repeater lenses etc. into the microoptical technology. Additional there are necessary new methods for handling and exact positioning. The discussed mounting equipment consists in a six-axis robot, some special developed grippers, a working station for the adjustment and a dosage device (ink-jet and stamp-transfer technique). In future some ideas for special equipments of precision mounting are to be realized. The range of accuracy contents about 0.5 - 5 mu m and some arcsec.