Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Entkeimen von Packstoffen beim aseptischen Abpacken. 10. Mitteilung. Entkeimen von Packstoffen beim Prozeß des Plastifizierens und Thermoformens in Form-Füll- und Verschließmaschine FS32b

Sterilization of packaging materials during aseptic packaging. Decontamination of packaging materials during the process of plastification and thermoforming in the form-fill- and seal-machine FS32b of Illig GmbH
 
: Cerny, G.

Verpackungs-Rundschau 43 (1992), No.4, pp.29-31 : Lit.
ISSN: 0042-4307
ISSN: 0341-7131
German
Journal Article
Fraunhofer ILV ( IVV) ()

Abstract
Experiments were performed in order to investigate if vegetative microorganisms like moulds or yeasts could be inactivated upon bottom films by passing a plasticizing and thermoforming device on a packaging machine. It could be demonstrated by machine runs on the thermoform-, fill- and seal machine FS 32 built by Adolf Illig Co. that the dry heat process mentioned resulted in an effective reduction of moulds and yeasts upon the packaging surface.

: http://publica.fraunhofer.de/documents/PX-12244.html