Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Capabilities and challenges in transferring the wavefront-based alignment approach to small aperture multi-element optical systems

 
: Krappig, Reik; Schmitt, Robert

:

Soskind, Y.G. ; Society of Photo-Optical Instrumentation Engineers -SPIE-, Bellingham/Wash.:
Photonic Instrumentation Engineering IV : 31 January-2 February 2017, San Francisco, California
Bellingham, WA: SPIE, 2017 (Proceedings of SPIE 10110)
ISBN: 9781510606616
ISBN: 9781510606623
Paper 101100A, 11 pp.
Conference "Photonic Instrumentation Engineering" <4, 2017, San Francisco/Calif.>
English
Conference Paper
Fraunhofer IPT ()
Wavefront sensors; wavefront based alignment; functional testing; Zernike coefficients; Montage; Optik; optische Messtechnik

Abstract
Present alignment methods already have an accuracy of some microns, allowing in general the fairly precise assembly of multi element optical systems. Nevertheless, they suffer decisive drawbacks, such as the necessity of an iterative process, stepping through all optical surfaces of the system when using autocollimation telescopes. In contrast to these limitations, the wavefront based alignment offers an elegant approach to potentially reach sub-μm accuracy in the alignment within a highly efficient process, that simultaneously acquires and evaluates the best optical solution possible. However, the practical use of these capabilities in corresponding alignment devices needs to take real sensor behavior into account. This publication will especially elaborate on the influence of the sensor properties in relation to the alignment process. The first dominant requirement is a highly stable measurement, since tiny perturbations in the optical system will have an also tiny influence on the wavefront. Secondly, the lateral sampling of the measured wavefront is supposed to be as high as possible, in order to be able to extract higher order Zernike coefficients reliable. The resulting necessity of using the largest sensor area possible conflicts with the requirement to allow a certain lateral displacement of the measured spot, indicating a perturbation. A movement of the sensor with suitable stages in turn leads to additional uncertainties connected to the actuators. Further factors include the SNR-ratio of the sensor as well as multiple measurements, in order to i mprove data repeatability. This publication will present a procedure of dealing with these relevant influence factors. Depending on the optical system and its properties the optimal adjustment of these parameters is derived.

: http://publica.fraunhofer.de/documents/N-456177.html