Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Machine components suitable for hygienic applications: A case study on cable glands

 
: Keller, Markus; Baum, Gabriela

:
Fulltext urn:nbn:de:0011-n-3372016 (1.4 MByte PDF)
MD5 Fingerprint: 96ceb9877a3bc795a111b5cc677ce186
Created on: 28.4.2015


European Hygienic Engineering & Design Group -EHEDG-:
EHEDG Yearbook 2015/2016
Frankfurt am Main: VDMA Verlag, 2015
ISBN: 978-3-8163-0667-2
pp.72-81
English
Book Article, Electronic Publication
Fraunhofer IPA ()
hygienic design; hygienische Fertigung; hygienisches Design; Kabelverschraubung; Reinheitszustand

Abstract
Where machines and equipment are constructed for use in hygienic manufacturing environments, they have to be designed with features that enable ease of cleaning. Several standards and guidelines state the main criteria and design recommendations for this. Media supply interfaces (electricity, compressed air, vacuum) at the transition point between cables/hoses and housings is the most common weak point as far as the ability to comprehensively clean such systems is concerned. Meanwhile, several solution recommendations for cable glands are now commercially available. In the following article, the cleanability of selected cable glands is investigated and assessed. A riboflavin test is utilized as a recognized and well-established method for visualizing and evaluating areas that are not reached by cleaning processes.