Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Progress in photovoltaic module calibration - results of a wordwide intercomparison between four reference laboratories

 
: Dirnberger, D.; Krälig, U.; Müllejans, H.; Salis, E.; Emery, K.; Hishikawa, Y.; Kiefer, K.

:
Postprint urn:nbn:de:0011-n-3154295 (6.3 MByte PDF)
MD5 Fingerprint: 3c204873e42d148d2e1fbe615f8da38d
Created on: 17.1.2015


Measurement Science and Technology 25 (2014), No.10, Art. 105005, 18 pp.
ISSN: 0957-0233
English
Journal Article, Electronic Publication
Fraunhofer ISE ()
Photovoltaische Module; Systeme und Zuverlässigkeit; Photovoltaische Module und Kraftwerke; Servicebereiche; Modulcharakterisierung

Abstract
Measurement results from a worldwide intercomparison of photovoltaic module calibrations are presented. Four photovoltaic reference laboratories in the USA, Japan and Europe with different traceability chains, measurement equipment and procedures, and uncertainty estimation concepts, participated. Seven photovoltaic modules of different technologies were measured (standard and high-efficiency crystalline silicon, cadmium telluride, single and double-junction amorphous and micromorph silicon). The measurement results from all laboratories and for all devices agreed well. Maximum power for the crystalline silicon samples was within ±1.3% for all thin-film modules roughly within ±3%, which is an improvement compared to past intercomparisons. The agreement between the results was evaluated using a weighted mean as a reference value, which considers results-specific uncertainty, instead of the widely used unweighted arithmetic mean. A further statistical analysis of all deviations between results and the corresponding reference mean showed that the uncertainties estimated by the participating laboratories were realistic, with a slight tendency towards being too conservative. The observed deviations of results from the reference mean concerned mainly short-circuit current and fill factor. Module stability was monitored through repeated measurements at Fraunhofer ISE before and after measurements at each of the other participating laboratories. Based on these re-measurements, stability problems that occurred for some thin-film modules and influenced the results were analyzed and explained in detail.

: http://publica.fraunhofer.de/documents/N-315429.html