Stress impact of moisture diffusion measured with the stress chip

 
: Schindler-Saefkow, F.; Rost, F.; Otto, A.; Pantou, R.; Mroßko, R.; Wunderle, B.; Michel, B.; Rzepka, S.; Keller, J.

:

Institute of Electrical and Electronics Engineers -IEEE-:
14th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems, EuroSimE 2013 : 14-17 April 2013, Wroclaw, Poland
New York, NY: IEEE, 2013
ISBN: 978-1-4673-6138-5
ISBN: 978-1-4673-6139-2
5 pp.
International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE) <14, 2013, Wroclaw>
English
Conference Paper
Fraunhofer ENAS ()

Abstract
The experimental observation of the actual thermo mechanical weak points in microelectronics packages remains a big challenge. Recently, a stress sensing system has been developed by the publicly funded project that allows measuring the magnitudes and the distribution of the stresses induced in the silicon dies by thermomechanical loads. Moisture can saturate a package very fast at high temperatures and high humidity within hours but also at low temperatures and low humidity within weeks or months. Every normal stored or used package will be swelled due to this moisture. A high temperature over a short time or within the first cycle of a temperature cycling test will dry the package and the internal stress of the package decrease. This moisture swelling will be investigated in this paper. All measurements are supplemented by finite element simulations based on calibrated models for in depth analysis and for extrapolating the stress results to sites of the package that are not measured directly. The methodology of closely combining stress measurements and FE simulation presented in this paper has been able to validate the stress sensing system for tasks of comprehensive design and process characterization as well as for health monitoring. It allows achieving both, a substantial reduction in time tomarket and a high level of reliability under service conditions, as needed for future electronics and smart systems packages.

: http://publica.fraunhofer.de/documents/N-264491.html