High resolution multichannel imaging systems

 
: Bräuer, A.; Brückner, A.; Wippermann, F.; Dannberg, P.; Leitel, R.

MOC 2011, 17th Microoptics Conference : 30.10.-2.11.2011, Sendai, Japan
Sendai, 2011
ISBN: 978-4-86348-182-4
pp.F-2
Microoptics Conference (MOC) <17, 2011, Sendai>
English
Conference Paper
Fraunhofer IOF ()

Abstract
Bio-inspired multichannel imaging systems bear the inherent advantage of shorter total track lengths compared to mono-channel imaging system. On the other hand, the attained resolution was rather poor up to now. In this paper we describe the realisation of a multichannel VGA camera. Sub-images are stitched together electronically in the so-called "electronic cluster eye" camera. Secondly, a close-up imaging system is shown, the "ultraflat microscope" achieving a resolution as high as 250 LP/mm. The essential optical elements for both systems are waferlevel fabricated micro-lens arrays.