Publica
Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten. Biomonitoring of benzene and toluene in human blood by headspace-solid-phase microextraction
| Fresenius Journal of Analytical Chemistry 363 (1999), pp.88-91 ISSN: 0937-0633 |
|
| English |
| Journal Article |
| Fraunhofer ITA ( ITEM) () |
| benzene; toluene; blood |
Abstract
A simple and rapid method for the determination of benzene and toluene in whole blood by headspace-solid-phase microextraction (HS-SPME) is described. Using SPME fibres coated with 65 ug carboxene/polydimethylsiloxane, limits of quantification (LOQ) of 5 ng/L for benzene and 25 ng/L for toluene are achieved. As a result of its large linear range (i. e. 5-5000 ng/L for benzene) the method is suitable for biomonitoring of both occupationally and environmentally exposed people. The reproducibility of the determination of benzene is <= 8%. An interlaboratory comparison demonstrated that the method proposed here compares favorably with existing methods (dynamic headspace, purge and trap).